Quantcast
Channel: EngineerZone: Message List
Viewing all articles
Browse latest Browse all 24339

AD9910 basic configuration

$
0
0

Hi all,

 

I want to help with a basic configuration of AD9910. I inherited a board with this chip after colleague who left our company.

The last three days I try to configure the AD9910 into a single tone mode...

 

The AD9910 on my board is clocked from a 25 MHz crystal oscillator. All his three profile select inputs are grounded (profile 0 selected) and SPI bus uses two separate data wires (SDI and SDO).

 

My configuration sequence is as follows. At first I reset the chip with impulse on a MASTER_RESET signal. Then I write the configuration registers and at the end I generate impulse on IO_UPDATE input.

When I try to read back all registers which I previously written down then I get the same values which I wrote there.

 

After this configuration sequence the AD9910 enables his PLL a generates internal system clock which is equal to 500 MHz. I am sure because I can measure the clock signal with frequency of 1/4 of internal system clock on pin SYNC_CLK (125 MHz).

 

Throught it all I am not able to generate required output sine signal.

 

I think that there in my configuration is some stupid mistake, but I can't to find it. I will be glad for any advice.

 

 

Libor

 

 

 

My configuration is:

CFR1 (0x00) = 0x00410002

Inverse sinc filter enable, sine output, SDIO is input only

 

CFR2 (0x01) = 0x01400020

Enable amplitude scale form single tone profiles, SYNC_CLK enable, disable sync timing validation

 

CFR3 (0x02) = 0x11100128

select VCO1, 262 uA, enable PLL, N = 20

 

Auxiliary DAC Control (0x03) = 0x0000007F

CODE = 127

 

Profile 0 (0x0E) = 0x3FFF00002C8B4395

FTW = 0x2C8B4395 -> fout = 87 MHz

ASF = 0x3FFF -> Maximum amplitude