Browse latest Browse all 24339

Re: AD8657ARMZ latch-up phenomena

$
0
0

AT,

 

  I don't know what your highest frequency is, but for driving 2-5 meters of cable and capacitance,

I would not use a micropower CMOS op amp;  they have wimpy output stages.  Depending on

how much supply current you can spare, I would look at:

AD4661-2, ADA4666-2, ADA4084-2, or ADA4096-2.

 

Harry