In our AD9361 Design we are not able to route all 8 Control Output Signals to the Baseband, although we may be able to connect a sub-set up, maybe 4 out of the 8. I'm trying to decide which 4 would be best. My first thoughts were to ignore any signals that could be inspected via the SPI. For instance I believe that "Rx RF PLL Lock" [Control Output Pointer = 0x01, Bit 6] is also available as SPI Register 0x247 D1. Is there a list available of alternative sources for the Control Output Signal contents, or do I need to laboriously cross-check through the AD9361 Register Map with the AD936x Control Output User Guide to try to associate the various signals?
I'm likely to give a high priority to the Gain Control Threshold Detector Signals, as I have not managed to find any of those available via the SPI. Have I just missed them in the register map?
Best Regards
Paul